Abstract

AbstractThe thermal conductivity at constant pressure of a collection of crosslinked, closed‐cell polyethylene foams were measured at room temperature with the transient plane source (TPS) method. The experimental results were compared with those determined by a standard steady‐state technique. The results showed that the values measured by the TPS method follow the same trends as those measured by a heat‐flow meter. Therefore, with the TPS technique it is possible to observe the influence of structural characteristics such as cell size, black carbon content in foams, density, and so forth on thermal conductivity. However, the values obtained by the transient method were approximately 20% higher than those given by the standard method. Possible reasons for these variations are discussed. © 2004 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 42: 1226–1234, 2004

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.