Flux decline in the dead-end ultrafiltration (UF) of binary solutions of bovine serum albumin (BSA, pI 4.7, MW 67,000) and hemoglobin (Hb, pI 7.1, MW 68,000) with polyethersulfone (PES, 100 kDa) and polyacrylonitrile (PAN, 100 kDa) membranes was studied. Key factors affecting the flux decline including solution pH (6.00–7.50), total protein concentration (1.5–9.0 μM), transmembrane pressure (TMP, 10–50 psi), and ionic strength (0.01–0.1 M) were systematically investigated. It was shown that the blocking filtration law could satisfactorily analyze the flux decline behavior. A simplified exponentially time-dependent model was adopted to describe the dynamics of flux decline during UF process, and used to determine the adequate time for membrane cleaning. The mechanism of membrane fouling was also analyzed by blocking filtration law, in which the standard blocking always dominated at the early stage in such UF processes. The fouling mechanism strongly depended on hydrophobic characteristics of the membranes, concentration and charge of the proteins, as well as pH and ionic strength of the solutions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.