Abstract

Linear equivalent circuit models are commonly used to estimate the effect of current ripple on the performance of water electrolyzers, thus it is important that the validity of this approach is examined. The effect of the amplitude and frequency of the sinusoidal current ripple on the performance of the alkaline water electrolyzer stack is studied experimentally. The increased current ripple amplitude produces additional losses in the electrolyzer stack, while the effect of ripple frequency appears to be insignificant. Linear models based on an equivalent circuit and polarization curve tangent are compared with waveform measurements with differing ripple amplitudes and frequencies to study their dynamic modeling capabilities. Under dynamic operation the experimental results show that operating voltage differs considerably from the static polarization curve, especially at low operating currents, due to nonlinear behavior. It is also shown that the dynamic equivalent circuit model using only linear components is not enough to accurately model electrolyzer behavior under dynamic operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.