Abstract

ABSTRACTA resistivity apparatus was developed to investigate the early hydration processes of cementitious materials cured at elevated temperatures. The apparatus consists of a temperature control system, resistivity measurement system, and automatic data acquisition system. The temperature control of the resistivity apparatus was ±0.5°C. Three parallel measurements varied by approximately 5%, which shows that the apparatus was reliable and reproducible. By monitoring the electrical resistivity of fresh cement, the hydration process was characterized. The developed device may provide valuable insights into the mechanisms of cement hydration at high curing temperatures. In addition, increased curing temperature accelerates the setting process and strength development of the cement. However, high temperature has negative effects on compressive strength of the material.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.