Abstract

Benign mediastinal cysts are challenging to diagnose. Although Endoscopic Ultrasound (EUS) and EUS-guided fine needle aspiration (FNA) can accurately diagnose mediastinal foregut cysts, little is known about their complications. This paper reports a rare case in which EUS-FNA performed on mediastinal hemangioma resulted in an aortic hematoma. A 29-year-old female patient was commissioned for EUS of an asymptomatic accidental mediastinal lesion. Chest CT revealed a 4.9×2.9×10.1 cm thin-walled cystic mass in the posterior mediastinum. EUS revealed a large, anechoic cystic lesion with a regular thin wall with negative Doppler. EUS-guided FNA was performed using a single-use 19-gauge aspiration needle (EZ Shot 3; Olympus, Tokyo, Japan), and approximately 70 cc of serous pinkish fluid was aspirated. The patient was in a stable condition with no signs of acute complication. One day after EUS-FNA, thoracoscopic resection for mediastinal mass was conducted. The purple and multi-loculated large cyst was removed. Upon removal, however, an aortic hematoma caused by a focal descending aortic wall injury was observed. After a few days of close observation, the patient was discharged upon stable 3D aorta angio CT findings. This paper reports a rare and severe complication of EUS-FNA, in which an aspiration needle caused a direct injury to the aorta. The injection must be performed carefully to avoid damaging the adjacent organs or digestive tract walls.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call