A 23-year-old female was referred to the University of Arkansas for Medical Sciences at 32 weeks' gestation with a history of aortic stenosis following aortic valve replacement. Evaluation by echocardiography showed an approximately 90 mmHg transvalvular pressure gradient. Pregnancy progressed to 36 weeks' gestation without problem, at which time the patient underwent cesarean section with lumbar epidural anesthesia. Invasive hemodynamic monitors were used to assess cardiac performance and as a guide for anesthetic management. The impact of aortic stenosis on pregnancy is discussed, as are management aspects of lumbar epidural anesthesia in such patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.