Abstract

Thoracic endovascular aortic repair (TEVAR) is used in the treatment of type B aortic dissections. Information related to aortic morphologic findings and the condition of the abdominal aorta after TEVAR is limited. To analyze aortic morphologic findings after TEVAR for type B aortic dissections. After a retrospective database review, the data for 30 patients who underwent TEVAR from January 1, 2007, through December 31, 2013, for type B aortic dissection were analyzed. Imaging software was used to calculate aortic diameters and volumes of the aorta on computed tomography (CT) or magnetic resonance imaging (MRI). Mean follow-up was 14.4 months. We performed TEVAR to cover proximal thoracic aorta tears in patients who underwent acute or chronic type B aortic dissections. Aortic morphologic findings of pre-TEVAR CT or MRI were compared with the most recent findings of post-TEVAR CT or MRI. Frequency of thoracic false lumen thrombosis (FLT) and false lumen patency (FLP) was determined and the effect on post-TEVAR aortic morphologic findings analyzed. Mean (SD) TEVAR increased true lumen diameter (19.50 [6.92] mm to 31.19 [5.36] mm, P < .001) and volume (77.92 [41.70] mL to 166.95 [69.69] mL, P < .001) and decreased false lumen diameter (29.77 [12.55] mm to 21.92 [12.05] mm, P = .001) on post-TEVAR CT or MRI when compared with pre-TEVAR scans. Seventy percent of patients experienced thoracic FLT; 30% had FLP. True lumen volume expansion and false lumen volume regression occurred in patients with FLT (82.07 [46.95] mm to 180.55 [77.99] mm, P < .001 and 161.84 [106.36] mm to 115.76 [140.77] mm, P = .002, respectively) and FLP (68.23 [21.43] mm to 128.22 [21.46] mm, P < .001 and 238.64 [174.00] mm to 198.93 [120.46] mm, P = .04, respectively). Patients with FLT had increased true lumen diameter (15.67 [6.43] mm to 26.13 [7.62] mm, P < .001) and volume (54.86 [30.52] mL to 88.08 [41.07] mL, P = .001) in the abdominal aorta after TEVAR, with no change in total abdominal aortic volume (161.94 [70.12] mL vs 160.36 [82.11] mL, P = .90). Total abdominal aortic volume significantly increased in patients with thoracic FLP (187.24 [89.88] mL to 221.41 [82.64] mL, P = .02). Favorable aortic remodeling of the thoracic aorta occurs after TEVAR for type B aortic dissections in patients with thoracic FLT and FLP. However, failure to achieve thrombosis of the thoracic false lumen negatively influences aortic morphologic findings of the contiguous abdominal aorta.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call