Abstract

Background The degree of aortic insufficiency (AI) after transcatheter aortic valve replacement (TAVR) has been identified as a predictor of increased mortality. Since even mild AI is associated with increased mortality in some studies, accurate quantification of post-TAVR AI is critical. Assessment of AI by echocardiography is typically performed by visual inspection and semi-quantitative methods. Most post-TAVR AI is paravalvular, however echocardiography has limited ability to quantify multiple eccentric paravalvular jets. Using flow quantification methods, cardiac MRI (CMR) may more accurately quantify AI severity post-TAVR and therefore more accurately assess risk in this population. Methods Twenty-three patients who underwent TAVR with a SAPIEN prosthesis were studied. All patients underwent an intraoperative transesophageal echocardiogram (TEE), as well as a post-procedure transthoracic echocardiogram (TTE) and CMR. Paravalvular AI by TTE and TEE was graded using color Doppler by quantifying the circumferential extent of AI as a percentage of the aortic annulus (none 30%) following recommendations from the Valve Academic Research Consortium. AI severity by CMR was quantified as the regurgitant fraction of forward aortic flow based on previously published recommendations (none 48%). Results The mean age was 79 +/- 10 years; 52% were men. TTE and CMR were performed at 1 [1-1] and 4 [1-4] days postTAVR respectively (median [IQR]). The left ventricular ejection fraction (LVEF) by CMR was 65 +/- 10%. AI severity by TTE was none in 9 (39.1%), trace in 11 (47.8%), and mild in 3 (13%) patients. TEE identified trace central AI in 6 patients (26%). Paravalvular AI by TEE was none in 4 (17.4%), trace in 14 (60.9%), and mild in 5 (21.7%) patients. AI by CMR was none in 2 (8.7%), trace in 5 (21.7%), mild in 13 (56.5%), and moderate in 3 (13%) patients; (Figure 1). A higher proportion of patients with mild or greater AI was identified by CMR (16/23, 70%) compared to TTE (3/23, 13%) and TEE (5/23, 22%); (Figure 2). Conclusions

Highlights

  • The degree of aortic insufficiency (AI) after transcatheter aortic valve replacement (TAVR) has been identified as a predictor of increased mortality

  • AI by cardiac MRI (CMR) was none in 2 (8.7%), trace in 5 (21.7%), mild in 13 (56.5%), and moderate in 3 (13%) patients; (Figure 1)

  • A higher proportion of patients with mild or greater AI was identified by CMR (16/23, 70%) compared to transthoracic echocardiogram (TTE) (3/23, 13%) and transesophageal echocardiogram (TEE) (5/23, 22%); (Figure 2)

Read more

Summary

Open Access

Wissam M Abdallah1*, Chris A Semder, Evan L Brittain, Michael T Baker, Lisa A Mendes, Marshall H Crenshaw, Joseph L Fredi, Mark A Robbins, Sonia L Scalf, William S Bradham, Sean G Hughes, Mark A Lawson, David X Zhao. From 17th Annual SCMR Scientific Sessions New Orleans, LA, USA. From 17th Annual SCMR Scientific Sessions New Orleans, LA, USA. 16-19 January 2014

Background
Methods
Results
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.