Abstract

Recent advances have allowed simultaneous hybrid repair with open surgical arch debranching and thoracic endovascular stent placement. We describe an asymptomatic patient with a degenerative aneurysm and concurrent coronary disease who successfully underwent a hybrid aortic arch and descending aorta repair and coronary revascularization. A 78-year-old man presented with a distal aortic arch aneurysm and two-vessel coronary disease. Preoperative computed tomography angiography demonstrated a fusiform aortic aneurysm involving the left carotid and subclavian arteries and proximal descending aorta. Catheterization revealed severe left anterior descending and diagonal branch coronary disease. After cardiopulmonary bypass was initiated, the left anterior descending and diagonal arteries were bypassed with saphenous venous grafts. Two openings were created at the sinotubular junction proximally, and coronary anastomoses were completed. Trifurcation graft (TG) with a separate branch for stent delivery was anastomosed to the proximal ascending aorta. The proximal clamps were then removed. The innominate artery was divided between clamps and then anastomosed to the main limb of the TG. Antegrade cerebral perfusion was established through the anastomosis. Next, the left carotid artery was anastomosed to the second limb of the TG, and antegrade cerebral perfusion was initiated using both arteries. Secondary to extensive atherosclerotic disease, the left subclavian artery was exposed using a left infraclavicular incision. The left subclavian was divided and then ligated at its origin. The third limb of the TG was brought into the left side of the chest and anastomosed to the subclavian artery. The patient was weaned off cardiopulmonary bypass. Initial aortic luminal flap noted the true lumen to be concave. A 40-mm × 15-cm Gore Thoracic TAG endoluminal stent graft (W. L. Gore & Associates, Flagstaff, Ariz) was deployed in the descending aorta proximal to the celiac artery under fluoroscopic guidance through a side branch of the TG. A second 45-mm × 20-cm Gore graft was deployed distal to the TG with significant overlap with the previous graft. Postprocedure completion aortography demonstrated no endoleak, and intravascular ultrasound noted the true lumen to be convex. One-month follow-up computed tomography scan showed the endograft without endoleak and patent bypass grafts. A hybrid approach allows the repair of the distal aortic arch and descending aorta as a one-stage procedure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.