Abstract

In this paper, three test models were cast about the grid -tube- type double steel plate and infilled concrete composite shear wall, the horizontal low cyclic loading test was carried out, and hysteresis curves and skeleton curves were got under different coaxial compression ratios. The results show that the new composite shear wall has many advantages, such as full hysteresis curve, high bearing capacity, high ductility and high energy dissipation capacity. Under the large displacement angle of 1/25 and cyclic loading of 80 times, the plastic hinge area still maintains the large stiffness and bearing capacity, which can effectively prevent the collapse of the structure under the action of a major earthquake. New composite shear wall has good seismic performance, which can realize the design requirements of high axial compression ratio, high ductility and thin thickness walls.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call