Abstract

We wished to determine the safety and anti-human immunodeficiency virus (HIV) type 1 activity of single doses of TNX-355, a humanized IgG4 anti-CD4 monoclonal antibody with potent activity against HIV-1 in vitro, in HIV-infected subjects. Sequential cohorts of 6 HIV-1-infected subjects each received infusions of TNX-355. Data included plasma HIV-1 RNA level, CD4+ T cell count, TNX-355 coating of CD4+ T cells, and serum TNX-355 levels. Dose-related reductions in plasma HIV-1 RNA loads correlated with complete CD4+ T cell coating by TNX-355. Peak median decreases in plasma HIV-1 RNA loads were 0.56, 1.33, and 1.11 log10 copies/mL and occurred on days 4-7, 14, and 21 for the 3.0, 10, and 25 mg/kg doses, respectively. Dose-dependent increases in CD4+ T cell count occurred within 24 h of dosing. Single doses of TNX-355 reduced plasma HIV-1 RNA loads and increased CD4+ T cell counts in HIV-infected subjects. The further assessment of therapeutic potential awaits data from longer-duration trials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.