Platelet antigens of platelet samples from 36 donors, frozen for different intervals, were evaluated by the platelet suspension immunofluorescence test (PSIFT). A, B, PLA1(HPA-1a) and various HLA antigens were tested by their corresponding antisera. The antigen could be detected in almost all the samples after one month of freezing. After 3 and 6 months, the platelet antigens could only be detected in 29.2% and 3.7% of the samples, respectively. There was no difference in decay of antigen expression among A, B, PLA1 and HLA antigens. When compared with the freshly prepared platelets, frozen platelets presented stronger antigen expression after 2 to 4 weeks of storage. This may suggest that the frozen platelets could be used for platelet crossmatching procedures without loss of their antigenicity within one month.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.