Abstract

Graphene oxide (GO), due to its excellent electrochemical properties and large surface area, known to be highly suitable material for biosensing application. Here, we report in situ synthesis of silver nanopaticles (AgNPs) onto the GO sheets for the electrochemical detection of Salmonella typhimurium (S.typhimurium). The GO-AgNPs composites have been deposited onto the indium tin oxide (ITO) coated glass substrate by the electrophoretic deposition technique. Carbodiimide coupling (EDC-NHS) has been used for the immobilization of antibodies of Salmonella typhimurium (anti-S.typhimurium) for detection of S.typhimurium. The electron microscopy and UV-visible studies reveal successful synthesis GO-AgNPs composites while FT-IR studies suggest the proper immobilization of anti-S.typhi. The cyclic voltammetry (CV) has been utilized for detection using anti-S.typhi/GOAgNPs/ITO based immunoelectrode as a function of S.typhimurium concentration. The fabricated immunosensor shows improved sensitivity of 33.04 μACFU-1mLcm-2 in a wide detection range of 101 to 106 CFUmL-1. This immunosensor may be utilized for the detection of other food borne pathogens like aflatoxin and E.coli also.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.