Abstract
AbstractBackgroundElastomeric infusion devices or âInfusorsâ are commonly used to administer 24âh continuous intravenous infusions to hospital patients at home, a service which can increase hospital capacity.AimThis study sought to determine Infusor efficiency by measuring infusion lengths administered by Infusors to patients in the community setting and reviewing any impacting factors on varying infusion rates, if observed.MethodPatients and nurses completed data collection forms daily over a 12âmonth period. The following information was recorded: time Infusor attached to patient, time Infusor emptied, Infusor âemptyâ or ânot emptyâ when removed, volume of antibiotic solution remaining, Infusor storage details, antibiotic solution and dose, indication for treatment, and date (season). Statistical analyses was conducted using Stata. Data were analysed using descriptive statistics, including median and range for continuous variables, and frequency counts and percentages for categorical variables. Ethical approval was granted by Northern Sydney Local Health District (NSLHD) Research Office (Reference no: RESP/14/184), the Human Research Ethics Committee (HREC) (Reference no: LNR/14/HAWKE/265) and the study conforms to the Australian National Statement on Ethical Conduct in Human Research. Informed consent was obtained from all participants via a study information leaflet that was provided with the patient questionnaire and patients were informed that their participation in the study was optional. Patients indicated their consent by completing the data collection form for each day of treatment.ResultsA significant number of Infusors (27%) emptied outside the expected infusion duration of 24 h ± 10% (21.6â26.4 h) and Infusors were removed ânot emptyâ when the nurse visited >24 h on 35% of occasions. Infusors were more likely to empty >24 h if they contained piperacillinâtazobactam 13.5 g (predicted probability = 1.0), in winter (predicted probability = 0.83), and in cooler overnight storage locations (predicted probability = 0.64). Infusors were more likely to empty <24 h if they contained vancomycin (predicted probability = 0.12).ConclusionInfusors delivering 24âh continuous intravenous infusions in the home setting may empty at unpredictable times and may be affected by temperature or solutions with varying doses. Outpatient parenteral antimicrobial therapy clinicians should be aware of possible unfinished infusions from Infusors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.