Silver (Ag) dots arrays (64 and 400 dots per mm2) are fabricated on a continuous platinum (Pt), palladium (Pd), or iridium (Ir) thin film (sacrifical anode systems for Ag) and for comparison on titanium (Ti) film (non‐sacrifical anode system for Ag) by sputter deposition and photolithographic patterning. The samples are embedded within a tissue‐like plasma clot matrix containing Staphylococcus aureus (S. aureus), cultivated for 24 h. Bacterial growth is analyzed by fluorescence microscopy. Among platinum group sacrifical anode elements and a dense Ag sample, only the high Ag ion releasing Ag–Ir system is able to inhibit the bacterial growth within the adjacent plasma clot matrix. This study demonstrates that the antibacterial efficiency of Ag coatings is reduced under tissue‐like conditions. However, the new sacrificial anode based Ag–Ir system can overcome this limitation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.