Abstract
According to the diversity of the pipeline vibration and unicity of vortex signal in direction, a new idea is proposed to distinguish the vortex signal from the vibration interference by the directional character. This idea is applied to improve the anti-vibration performance of vortex flow-meter by a new probe structure based on three-axis accelerometer. Then model analysis is used to optimize the material, and the harmonic response analysis is applied to optimize the shape of probe tip. Finally, experiment is carried out to compare the anti-vibration performance of the traditional piezoelectric vortex probe and the new design. Experimental results show that new probe can accurately distinguish vortex signal from the vibration interference according to the directional character of signal. And its anti-vibration performance is superior to the traditional piezoelectric vortex probe.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.