Abstract

We report the case of a 59-year-old multiple myeloma patient in whom an anti-human thrombin IgA antibody led to prolonged in vitro coagulation times, suggesting inhibitors to all intrinsic coagulation factors in the absence of spontaneous bleeding. Routine and extensive special coagulation tests, in vivo bleeding time, and specific antibody testing were performed. Although the patient did not suffer from spontaneous bleeding and had a normal in vivo bleeding time, the anti-human thrombin IgA autoantibody affected all coagulation assays involving human thrombin in vitro, mimicking inhibitors to intrinsic coagulation factors. As the IgA paraprotein and the IgA antibody virtually disappeared after autologous stem cell transplantation, the coagulation tests also largely normalized. Antibodies to human thrombin may interfere with all coagulation assays involving thrombin, imitating a severe coagulopathy. However, in vivo they do not necessarily lead to strongly increased bleeding tendency. Complex and ambiguous coagulation abnormalities should be evaluated and treated in an interdisciplinary setting, including a highly specialized coagulation laboratory, from the beginning.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call