Abstract

Wearable multi-physiological parameter monitoring technology can realize non-intrusive, non-invasive daily health monitoring of the human body. It has the characteristics of convenient operation, long-term continuous work, display of results, abnormal physiological condition alarm and wireless data transmission. First, an improved sliding window confidence propagation algorithm is proposed, which reduces the inefficient iterative process in the decoding process by correlation coefficients and reduces the running time of the algorithm by more than 1.5 times; designing a channel noise estimation method based on sliding window confidence propagation algorithm, and The source coding is similar. In order to estimate the local statistical parameters of the channel noise, the confidence propagation, the decoder uses the local partial probability of the adjacent accompanying child nodes to estimate the noise parameters of the channel noise. Secondly, the design and research of the blood oxygen saturation monitor, including filtering out high-frequency glitch noise, low-frequency baseline drift noise, and mixing and sudden motion interference noise, also achieved rapid and accurate extraction of pulse wave feature points, and calculated the blood oxygen value and pulse rate value. Compared with the traditional oximeter, the filtering algorithm and pulse wave feature point extraction algorithm on the oximeter software have less calculation amount and higher real-time performance. Finally, the relevant test experiment of the blood oxygen saturation monitor proves that the blood oximeter has good stability, accuracy and sensitivity. The practical use of anti-motion interference wearable devices not only shows that the wearable PPG sensor in this paper can stably obtain high-quality PPG signals, but also reflects its many applications in the field of real-time blood.

Highlights

  • Blood oxygen saturation characterizes the oxygen content of the human blood, can effectively reflect the physiological state of the human circulatory system and respiratory system, and plays an active role in the diagnosis and health monitoring [1]

  • Obtain blood oxygen saturation information [4], [5]; another example is the soldiers in the battlefield environment, which can obtain their blood oxygen saturation status in real time, which can effectively and timely determine whether the soldiers have tension pneumothorax or suffocation caused by VOLUME 8, 2020

  • The experimental results in this paper prove the rationality of the designed model, and verify that the method of using red light channel, green light channel and differential channel to simultaneously collect pulse wave signals to improve the system’s ability to resist motion interference is feasible and can improve signal noise ratio

Read more

Summary

Introduction

Blood oxygen saturation characterizes the oxygen content of the human blood, can effectively reflect the physiological state of the human circulatory system and respiratory system, and plays an active role in the diagnosis and health monitoring [1]. C. NON-STATIONARY CHANNEL PARAMETER ESTIMATION BASED ON SLIDING WINDOW CONFIDENCE PROPAGATION ALGORITHM In the joint source channel coding, the transmission channel is generally a noisy channel.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.