Abstract
ABSTRACT: The capabilities of mass spectrometry for microscale determination of anthocyanins were investigated using high-performance liquid chromatography electrospray ionization mass spectrometry (LC-ESI/ MS) and tandem mass spectrometry (MS-MS). Four anthocyanins [cyanidin 3-glucoside, cyanidin 3-sambubioside, cyanidin 3–(2G−xylosylrutinoside) and cyanidin 3-rutinoside] were characterized in black raspberry samples by LC-ESI/MS-MS using both positive and negative ion analyses. Quantification of anthocyanins was conducted using ESI/MS-MS with selected reaction monitoring (SRM). Linear responses of several anthocyanins were determined during MS-MS analyses. Detection limits as low as 1 femtomol for most anthocyanins were obtained during ESI/MS-MS. Compared with other quantitative procedures such as high-performance liquid chromatography (HPLC) and ultraviolet/visible spectrophotometry, the current method provides an improved sensitive, specific technique for direct determination of intact anthocyanins. The developed methodology was successfully applied to analysis of trace levels of anthocyanins in human plasma and epithelial cells.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.