Abstract

ObjectiveIn patients with residual poliomyelitis-related impairments, total hip arthroplasty (THA) is challenging due to the high frequency of risk factors such as hip dysplasia, dislocation, muscle weakness, and fracture. The objective of this study was to assess the long-term functional and radiographic outcomes of anterior-approach THA with a ceramic-ceramic, dual-mobility, or constrained implant in patients with poliomyelitis sequelae. HypothesisTHA via the anterior approach with a ceramic-ceramic, dual-mobility, or constrained implant is a reliable technique that is not associated with excess risks of instability or aseptic loosening. Material and methodsThis single-centre retrospective study included consecutive patients with poliomyelitis sequelae who underwent THA between January 1998 and September 2019 via the anterior approach, with implantation of a ceramic-ceramic, dual-mobility, or constrained implant. The Harris Hip Score (HHS), implant position, and complications (e.g., infection and loosening) were collected during the most recent in-person visit. ResultsThe study included 19 patients (23 hips). Mean follow-up was 5.2 ± 4.2 years (range, 2.0–10.6 years). Only six of the 23 procedures were done on the side with greater muscle weakness. The mean HHS at last follow-up was 80.4 ± 10.4. A single procedure (1/23, 4%) was followed by a complication, consisting in intra-prosthetic dislocation 2 years after implantation of a dual-mobility cup. At last follow-up, the HHS was not associated with psoas and gluteus muscle strength (rs = 0.35, p = 0.11 and rs = 0.37, p = 0.09, respectively) and was not significantly different between the weaker vs. stronger side (82.7 ± 8.0 vs. 79.5 ± 11.3, respectively; p = 0.53). Cup position was more horizontal, thereby optimising function, when the procedure was done on the weaker vs. the stronger side (39.9° ± 4.3 vs. 45.0° ± 6.8, respectively; p = 0.02). ConclusionTHA is a good option for improving function in patients with poliomyelitis sequelae. THA via the anterior approach with a ceramic-ceramic, dual-mobility, or constrained implant is a reliable method that is not associated with an excess risk of instability or loosening. Level of evidenceIV.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.