Abstract

To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8years. The preoperative IOP was 15.02mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58dB. The meanIOP reduction was 2.1mm Hg (12.8%) from a preoperative mean of 15.0mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P=.002). In multivariate analysis, preoperative IOP (β=-0.53, P<.001, R2=0.40), angle-opening distance at 500mm (β=5.83, P=.02, R2=0.45), angle-opening distance at 750mm (β=5.82, P=.001, R2=0.52), and lens vault (β=-0.002, P=.009, R2=0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call