Abstract
The use of recombinant human bone morphogenetic protein-2 (rhBMP-2) in anterior lumbar interbody fusion (ALIF) is controversial regarding the reported complication rates and cost. The authors aimed to assess the complication rates of performing ALIF using rhBMP-2. This is a prospective study of consecutive patients who underwent ALIF performed by a single spine surgeon and a single vascular surgeon between 2009 and 2012. All patients underwent placement of a polyetheretherketone (PEEK) cage filled with rhBMP-2 and a separate anterior titanium plate. Preoperative clinical data, operative details, postoperative complications, and clinical and radiographic outcomes were recorded for all patients. Clinical outcome measures included back and leg pain visual analog scale scores, Oswestry Disability Index (ODI), and SF-36 Physical and Mental Component Summary (PCS and MCS) scores. Radiographic assessment of fusion was performed using high-definition CT scanning. Male patients were screened pre- and postoperatively regarding sexual dysfunction, specifically retrograde ejaculation (RE). The study comprised 131 patients with a mean age of 45.3 years. There were 67 men (51.1%) and 64 women (48.9%). Of the 131 patients, 117 (89.3%) underwent ALIF at L5-S1, 9 (6.9%) at L4-5, and 5 (3.8%) at both L4-5 and L5-S1. The overall complication rate was 19.1% (25 of 131), with 17 patients (13.0%) experiencing minor complications and 8 (6.1%) experiencing major complications. The mean estimated blood loss per ALIF level was 115 ml. There was 1 incidence (1.5%) of RE. No significant vascular injuries occurred. No prosthesis failure occurred with the PEEK cage and separate anterior screw-plate. Back and leg pain improved 57.2% and 61.8%, respectively. The ODI improved 54.3%, with PCS and MCS scores improving 41.7% and 21.3%, respectively. Solid interbody fusion was observed in 96.9% of patients at 12 months. Anterior lumbar interbody fusion with a vascular access surgeon and spine surgeon, using a separate cage and anterior screw-plate, provides a very robust and reliable construct with low complication rates, high fusion rates, and positive clinical outcomes, and it is cost-effective. The authors did not experience the high rates of RE reported by other authors using rhBMP-2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.