Abstract

Femoropatellar problems have been reported with some designs of posterior-stabilized knee prostheses with fixed bearings; we report similar findings with a posterior-stabilized mobile-bearing prosthesis. A review of 184 patients (193 knees) who underwent placement of a Rotaglide (Corin, Cirencester, UK) posterior-stabilized prosthesis with patellar resurfacing showed that only 33 knees (17%) had complete absence of femoropatellar complaints after at least 1 year of follow-up evaluation. Femoropatellar grinding was noted in the other 160 knees; 65 were asymptomatic, 78 were mildly symptomatic, and 17 were severely symptomatic. Two patients refused secondary treatment; 15 underwent arthroscopic debridement. The only abnormal finding was intra-articular fibrosis surrounding the patellar implant. After arthroscopic debridement of the fibrosis, all patients reported immediate relief of their symptoms followed by recurrence within 6 to 9 months. Inappropriate trochlear design of the femoral implant appears to be the main determinant of femoropatellar problems in these patients. Encroachment on the trochlea by a broad intercondylar box with a sharp anterior edge appears detrimental to function irrespective of the presence or absence of bearing mobility.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.