Abstract

<p class="abstract"><strong>Background:</strong> The cut of the anterior femur (CAF) sets the rotation of the femoral component, which could affect patellar tracking, and influence the clinical results on total knee arthroplasty (TKA). The aim of this study was to suggest a classification for anterior femoral cut in TKA.</p><p class="abstract"><strong>Methods:</strong> Images of anterior femoral cuts were aggregated in different shapes and defined a classification. One-hundred femoral image’s cuts were analysed by 5 orthopaedic surgeons, which classified them twice. To analyse inter and intra-observer agreement, the Fleiss Kappa test was used.<strong></strong></p><p class="abstract"><strong>Results:</strong> The study proposes the following CAF classification, type 1 (one peak) and type 2 (two peaks); subtypes 1 (a) a central base peak, 1 (b) a lateral base peak, 2 (a) two peaks where the smallest is in the lower half, and 2 (b) two peaks where the smallest is in the upper half. In our study, type 2 (a) was the most common type (54.5%), followed by type 1 (b). The analysis showed good intra- and inter-observer agreements (mean K of 0.774 and 0.627, respectively). The intra and inter-observer concordance was statistically significant in all the analyses.</p><p class="abstract"><strong>Conclusions:</strong> The CAF classification system for TKA is considered a reproducible classification. To our knowledge, there is no study describing a shape’s classification of this cut. A slight rotation of the femoral cutting guide could change the axial rotation and positioning of the femoral component. An undesirable cut could lead to different patellofemoral offset and could consequently cause anterior pain and instability.</p>

Highlights

  • Total knee arthroplasty (TKA) is surgical procedure for the treatment of end-stage knee arthritis, with an overall high clinical success

  • The anterior femoral cut sets the rotation of the femoral component, which affects patellar tracking, it is an extremely important step on total knee arthroplasty.[4]

  • A few previous studies exist on the accuracy of femoral component rotation using Patient Specific Instrumentation in Total Knee Arthroplasty (PSI-total knee arthroplasty (TKA))

Read more

Summary

Introduction

Total knee arthroplasty (TKA) is surgical procedure for the treatment of end-stage knee arthritis, with an overall high clinical success. The anterior femoral cut sets the rotation of the femoral component, which affects patellar tracking, it is an extremely important step on total knee arthroplasty.[4]. Tayside classification studies the relationship between anterior femoral notching and a risk of fracture, but the analysis is in lateral view and it is not the most suitable to determine the shape of anterior part of femur. To determine the proper femoral component rotation, several surgical methods have been utilised, like the transepicondylar line, the Whiteside line or the posterior condylar line. A few previous studies exist on the accuracy of femoral component rotation using Patient Specific Instrumentation in Total Knee Arthroplasty (PSI-TKA). The cut of the anterior femur (CAF) sets the rotation of the femoral component, which could affect patellar tracking, and influence the clinical results on total knee arthroplasty (TKA). An undesirable cut could lead to different patellofemoral offset and could cause anterior pain and instability

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call