Abstract

The cross-pin femoral fixation technique for soft tissue grafts is a popular option in anterior cruciate ligament (ACL) reconstruction. One of these devices is the Bio-TransFix (Arthrex Inc., Naples, FL, USA) which provides high fixation strength. According to the manufacturer, the femoral tunnel is created by placing the femoral aiming device through the tibial tunnel (transtibial technique). However, using this technique it is very difficult or even impossible to place the graft at the anatomical ACL attachment site at the "10 o'clock" position. In this report, we describe the use of the Bio-TransFix device with an anteromedial portal technique. Using this technique, the surgeon has more freedom to place the graft in an anatomical position, while combining the advantages of the excellent biomechanical properties of this device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.