Abstract

Background:Compartment syndrome is a potentially devastating condition. Increased intracompartmental pressure has been incriminated as the primary pathogenic factor in compartment syndrome. The purpose of this prospective study was to monitor the anterior compartmental pressure and differential pressure to minimize the incidence of acute compartment syndrome.Materials and Methods:Seventy-five consecutive cases of closed fractures of leg presenting within six hours of injury were taken for measurement of anterior compartment pressure at the level of fracture and at 5 cm and 10 cm away from the fracture site, using the Whitesides' infusion technique. A differential pressure of less than 30 mm Hg was taken as the criterion for diagnosis of compartment syndrome.Results:Two patients (2.67%) developed acute compartment syndrome. The mean anterior compartment pressures were highest at the level of the fracture and went on decreasing as we went away from the fracture site, which was found to be statistically significant (P < 0.001).Conclusion:Compartment pressure measurement is the most reliable and objective method for early diagnosis of compartment syndrome. Whitesides' infusion technique is a relatively easy and inexpensive method to come to a diagnosis of compartment syndrome in a developing country like India. Differential pressure is more reliable than absolute pressure in predicting the development of an impending compartment syndrome.