Abstract

This study determined the rate of anterior chamber aerobic bacterial contamination in 103 eyes that had uncomplicated posterior chamber phacoemulsification. Anterior chamber fluid was aspirated on completion of surgery. Cultures of sterile balanced salt solution served as a control. Of 103 anterior chamber cultures, 4 (3.9%) showed contamination; however, 3 of 103 control cultures (2.9%) also grew micro-organisms. These findings suggest a very low rate of aerobic bacterial contamination after uncomplicated phacoemulsification and underscore the importance of control cultures when determining contamination rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.