Abstract

The conventional approach for antegrade intramedullary nailing (AIN) of humerus fractures is associated with persistent pain and compromised shoulder function. Damage to the critical hypovascular zone of the rotator cuff near its insertion on the humerus and/or irritation of the subacromial space by prominent hardware are the factors believed to be responsible for poor shoulder function after AIN of the humerus. This study describes a new entry portal through the rotator interval that minimizes iatrogenic damage to the rotator cuff at its insertion. This approach offers a solution for the disappointing postoperative shoulder function and pain scores associated with conventional antegrade nailing techniques. This study consisted of 33 patients with 34 humeral fractures followed for an average of 34 months. The overall satisfaction rate was more than 90%, according to the ASES (American Shoulder and Elbow Society) score. The mean Constant Score was 84 (SD, 14; range, 17 to 98), and primary bone union was achieved in 32 of the 34 cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.