Abstract

Bioelectrochemical treatment system (BET) with anoxic anodic microenvironment was studied with chemical wastewater (CW) in comparison with anoxic treatment (AxT, sequencing batch reactor (SBR)) with same parent anaerobic consortia. BET system documented relatively higher treatment efficiency at higher organic load (5.0 kg COD/m(3)) accounting for COD removal efficiency of (90%) along with nitrate (48%), phosphate (51%), sulphates (68%), colour (63%) and turbidity (90%) removal, compared to AxT operation (COD, 47%; nitrate, 36%; phosphate, 32%; sulphate, 35%; colour, 45% and turbidity, 54%). The self-induced bio-potential developed due to the electrode assembly in BET resulted in effective treatment with simultaneous bioelectricity generation (631 mA/m(2)). AxT operation showed persistent reduction behaviour, while simultaneous redox behaviour was observed with BET indicating balanced electron transfer. BET operation illustrated higher wastewater toxicity reduction compared to the AxT system which documents the variation in bio-electrocatalytic behaviour of same consortia under different microenvironment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.