Abstract

Oscillations of the main parameters (voltage on electrodes, potential, light intensity and discharge current) in a dc atmospheric-pressure glow discharge in helium are investigated in a range of currents from milliamperes to several amperes. It is established that these oscillations are connected with the existence of anode spots. In the case of a single spot, fluctuations of discharge light intensity are observed when the supply voltage exceeds the breakdown voltage for the interelectrode gap. At the same time, voltage fluctuations have the form of relaxation oscillations with a frequency that depends on the electrical parameters of the external circuit. With an increase in discharge gap and current, the number of spots increases. They form a stable structure, and the fluctuations of current and voltage stay harmonic. The brightness of the spots seems to be determined by the frequency of their blinking. The amplitude of current fluctuation increases with the increase in discharge current and can be up to 15% of its average value. The frequency of current oscillations, which is about 0.75 MHz at a current of 0.5 A, depends weakly on the discharge gap (it varies within ±10% for the gap interval from 1 to 10 mm). The oscillation frequency is maximal (about 0.85 MHz) at a current of about 0.4 A. At higher currents (2–4 A, depending on the discharge gap), the fluctuations disappear when a contraction of the anode region into one anode spot occurs.