Abstract

This paper reports the annual as well as seasonal performance analysis of single-slope passive solar stills having three different inclinations of condensing cover, namely 15, 30 and 45°. The analysis is based on the experiments conducted throughout the year from June 2004 to May 2005 on one clear day every month. Each experiment has been carried over for 24 h for the New Delhi (Latitude: 28°37′ North and Longitude: 77°13′ East) climatic conditions. It was observed that the 15° inclination of condensing cover gives maximum annual yield and distillation efficiency. The concept of solar fraction has been used for the validation of thermal modelling. The fair agreement has been noted between the values observed experimentally and calculated theoretically for temperatures and yield in all seasons. Copyright © 2007 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.