Abstract

To investigate annual fluctuation of internal temperature and humidity of concrete members, we measured and analyzed them in outer wall and balcony slab in a 46-year-old RC building. The results showed that annual average of internal temperature is higher by 1~6 degree C than air temperature mainly because of solar radiation, which leads to decline of water content and average internal humidity. Increase of internal temperature is also responsible for temporary increase of internal humidity. Comparison of the humidity fluctuation at the same range of internal temperature can enable to evaluate fluctuation of water content.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.