Abstract

The short- and long-term anneal of radiation-induced flatband voltage shift in both Al- and Si-gate MOS capacitors following pulsed e-beam irradiation is examined. The short-term anneal was measured and found to be similar for both Al- and Si-gate capacitors. Experiments were performed to investigate the dependence of the long-term anneal on oxide thickness, temperature, and bias. The Al-gate capacitors exhibited a low interface-state buildup following irradiation and had a long-term annealing curve with a simple ln(t) dependence, while the Sigate capacitors studied had a more complicated annealing curve due to the buildup of a larger number of interface states and lateral nonuniformities (LNUs). Thinning the gate oxide was found to dramatically reduce the effects of interface states and LNUs on the long-term anneal. In capacitors where the effects of interface states and LNUs are small the long term annealing was found to be only weakly temperature dependent over the range -60 to 100°C, and removal of bias following irradiation had little effect. On the other hand, the long-term annealing of capacitors with a significant buildup of radiation-induced interface states and LNUs exhibited a strong temperature and post-radiation bias dependence. Some implications of the experimental results for the proper design of test procedures for determining radiation susceptibility are discussed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call