Abstract

Of consecutive patients seen with first myocardial infarction (88 of whom were treated out-of-hospital by mobile coronary care staff), 139 received 30 units of intravenous anistreplase at a mean of 101 minutes (range 35–180) from onset of symptoms. Thrombolysis in myocardial infarction patency grade 2 or 3 was found in 76 91 (83.5%) patients. At 3–4 months after hospital discharge, the mean global left ventricular ejection fraction and mean infarct-related regional third ejection fraction declined with increasing delay to anistreplase. For the first, second and third hour administrations, global ejection fraction was 54%, 50% and 45% ( P = 0.002) and for regional third ejection fractions 49%, 43% and 41% ( P = 0.02) respectively. Of the patients, 130 were reviewed at approximately 1 year: reinfarction had occurred in 9, 6 had undergone coronary angioplasty and 1 had coronary arterial bypass grafting performed since discharge. Mean global left ventricular ejection fraction was 52% and mean infarct-related regional third ejection fraction was 51%. Thus, intravenous anistreplase induces high rates of arterial patency. Global and regional third ejection fractions decline with increasing delay in the time of administration of anistreplase. Mortality and morbidity is low in the first year.