Abstract

Defects such as cracks can cause dangerous damage to the metal structure and may lead to structural collapses. Cracks can exist in various shapes and sizes where they can start to develop from small scale lower than 1 mm and spread to contribute to the complete fracture of components. Hence, early discovery and monitoring of any cracks in their early stage are crucial to prevent any sudden fatal accidents in the future. This work presents the study and detailed analysis of an ECT probe’s development based on AMR sensors to identify sub-millimeter surface cracks in galvanized steel plates. The probe consists of an excitation coil that induces an eddy current in sample plates and two AMR sensors that detect the differential eddy current-induced magnetic response. A phase-sensitive detection technique with a lock-in amplifier is used to evaluate the magnetic field distribution detected by the AMR sensors. The measured magnetic responses are classified to the depth, width, length, and complex shapes of artificial slits, and the probe is used to perform line scans and 2-D map scans above the slits’ positions. The probe was able to characterize slits with a depth and width as low as 210 and 50 µm, respectively, by using an excitation current of 4 mA at 1 kHz. The slit orientations that were perpendicular to the differential direction of the AMR sensors were clearly visualized, with their estimated lengths showed a good correlation with the physical slit lengths. In the future, the developed system can be expected to help towards the development of a more sophisticated crack detection system where real-time inspections can be realized and applied in various fields.

Highlights

  • Characterization of magnetic field distributions induced by defects is a promising technique for NDT of steel materials since they are non-contact, rapid, and safe

  • Surface and subsurface cracks are one of the defects that must be monitored in order to avoid accidents that can lead to severe injury or death.[3]

  • Since the anisotropic magnetoresistance (AMR) sensor is relatively small in size, the eddy current testing (ECT) probe size can be further compacted compared to the use of coil while addressing the magnetic noise issue in conductive materials

Read more

Summary

Introduction

Characterization of magnetic field distributions induced by defects is a promising technique for NDT of steel materials since they are non-contact, rapid, and safe. This magnetic field characterization procedure possesses an advantage in which it can be compacted since its system configuration is simple. Methods that use this technique include the eddy current testing (ECT) method, where in NDT, ECT is broadly used for the evaluation of conductive components such as metallic plates.[1,2]. The structural safety of samples under test must be ensured where a continuous inspection without causing any deterioration of them is needed

Objectives
Methods
Results
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call