Abstract

The long-lived positron emitter 89Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89Zr for clinical use are traditionally performed with a single hydroxamate resin column. Herein, we present a tandem column purification method for the preparation of high-purity 89Zr from cyclotron bombarded natural Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 μL, is packed with an extraction chromatography resin (ExCR) loaded with di-(2-ethylhexyl)phosphoric acid (HDEHP). A condition of “inverted selectivity” is presented, wherein the 89Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential purification steps to be performed prior to the final elution of the 89Zr product. This approach assures delivery of high purity 89Zr. The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7 ± 2.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89Zr product volume of ∼0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([MB]) that exceed those reported by the traditional single hydroxamate column method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.