Abstract

Parallel beam laser vibrometers offer direct measurement of pitch and yaw vibration directly from rotors. This paper, intended as an essential guide for the practical parallel beam laser vibrometer practioner, presents exact mathematical expressions for measured angular velocity in the presence of inevitable misalignments and estimates the likely measurement error levels due to such misalignments as well as to other sources of uncertainty through numerical simulation. Cross-sensitivity to the orthogonal vibration component, i.e. cross-sensitivity in a pitch measurement to yaw motion and vice-versa, is confirmed for rough rotors whereas it is shown not to be present when rotors are polished-circular. A complementary experimental investigation of the relationship between surface roughness and cross-sensitivity confirms the identification of two preferred measurement configurations: from the side of a polished-circular rotor and from the end face of a (rough) rotor coated in retro-reflective tape. Rotors with surface roughness up to 50nm satisfy the former case provided the vibration displacement at the rotor surface does not exceed 20% beam diameter. For surfaces with roughness of 10nm this can be extended to 50%. For rough rotor end face measurements, post-processing is required to resolve the inherent cross-sensitivity; the need for post-processing is justified quantitatively through numerical simulation. Further simulations incorporating typical levels of instrument misalignment and measurement noise are used to enable quantification of the likely errors in such angular vibration measurements. For measurements from the side of a polished-circular rotor, errors are around 1% for amplitude and 10mrad at integer orders affected by pseudo-vibration and around one-third of these levels elsewhere. For measurements from a rough rotor end face, errors will be similar at integer orders (from 2). Errors in the rotational speed measurement, required for post-processing, must be minimised in order to limit errors up to 2nd order while misalignments determine errors at around 0.4% amplitude and 4mrad phase at orders above 2 other than at the integer orders.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.