Abstract

The angular distribution of the 14 MeV neutrons emitted through D–T reaction was measured around the tritium target of a 14 MeV neutron generator using two different sample holders and also theoretically estimated. The samples were made out of 99.99% pure Aluminium foil and irradiated with the neutrons. In the neutron irradiated aluminum samples, the gamma-ray activity, induced through the nuclear reaction Al 27 (n,α)Na 24 was measured by a NaI(Tl) detector. Using one of the sample holders the axial distribution of neutron flux was also estimated. The discrepancy from the isotropic pattern was accounted for by reasons related to the in-between matrices and design of the tritium target mounting assembly.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.