Abstract
Compact wavelength splitters based on angled multimode interferometers (AMMIs) on silicon nitride platforms working in visible lights are reported for fluorescence sensing applications. A diplexer and triplexer with different footprints are designed and experimentally demonstrated. The diplexer and triplexer have the insertion loss of ∼1.7 and ∼2.7 dB/channel with cross talks of less than -22 dB and -17 dB on target wavelengths, respectively. These splitters are used to distinguish the signals collected from two fluorescent dyes that give different emission spectra when excited with an excitation source, due to their different Stokes shifts. In the case of the triplexer, a third port is to collect the excitation light, both to monitor the remaining excitation power and to reduce the interference at the signal ports. A termination structure at the end of the AMMIs and input and output tapering waveguides as a part of the wavelength splitters are designed and their performances are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.