Abstract

Polarization cameras quantify one of the fundamental properties of light and capture intrinsic properties of the imaged environment that are otherwise omitted by color sensors. Many polarization applications, such as underwater geolocalization and sky-based polarization compass, require simultaneous imaging of the entire radial optical field with omnidirectional lenses. However, the reconstructed angle of polarization captured with omnidirectional lenses has a radial offset due to redirection of the light rays within these lenses. In this paper, we describe a calibration method for correcting angle of polarization images captured with omnidirectional lenses. Our calibration method reduces the variance of reconstructed angle of polarization from 76.2 ∘ to 4.1 ∘. Example images collected both on an optical bench and in nature, demonstrate the improved accuracy of the reconstructed angle of polarization with our calibration method. The improved accuracy in the angle of polarization images will aid the development of polarization-based applications with omnidirectional lenses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.