Abstract

The importance of port closure after laparoscopic surgeries is emphasized by the extensive number of techniques being described for the same. Even so, the search for a simple, time-saving, and effective technique still continues. One commonly overlooked factor is the obliquity of laparoscopic ports, which makes direct visualization of the rectus fascia through the skin incision difficult. Also, our patients, mostly of Indian ethnicity, tend to have relatively thick subcutaneous fat that again acts as a constraint during port closure. We have described a simple and effective method of laparoscopic port closure using Moynihan's aneurysm needle and a skin hook. This technique is particularly advantageous in the above-mentioned scenarios. We have been successfully using this technique in our institution for the past 6 years, and we have not encountered any case of port-site hernia. Our technique does not require expensive instruments or the need for visualization via a camera.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.