Abstract
The anchorage performance of headed deformed bars anchored in inter-story exterior beam-column joints under cyclic load was examined based on a test database with 118 test data. A proposed performance index based on the ACI 318 development length equation was used to evaluate the anchorage performance of the headed deformed bars of the specimens in the database. The results of the evaluation showed that the anchorage performance was positively correlated with the axial load, amount of joint transverse reinforcement parallel to the direction of applied shear, and head bearing area ratio, and was negatively correlated with the clear bar spacing and column moment ratio. Based on the evaluation, limits on design parameters (i.e., the minimum clear bar spacing, head bearing area ratio, concrete and steel strengths) were proposed. It was found that all the specimens in the test database showed satisfactory seismic performance if they satisfied the development length equation of the ACI 318 code and the proposed limits on design parameters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.