Abstract

Vaginal mesh attachment can be one of the most time-consuming components of a minimally invasive sacrocolpopexy. To assess the impact on the duration vaginal mesh attachment of using absorbable anchors compared to interrupted sutures for vaginal mesh attachment in robotic-assisted sacrocolpopexy. This was a single-masked, randomized clinical trialof women with pelvic organ prolapse that underwent a robotic-assisted sacrocolpopexy at 2 clinical sites. The participants were randomized to receive either interrupted delayed absorbable anchors orsutures during the vaginal mesh attachment portion of the surgery. The participants completed validated questionnaires at baseline andat 6 weeks, 6 months, and 12 months after the surgery. A certified examiner, masked to the attachment technique that was used, performed a clinical examination using the Pelvic Organ Prolapse Quantification system and also assessed for mesh exposure and the overall appearance of the vaginal walls using a 10-cm visual analog scale at each follow-up visit. The primary outcome was the vaginal mesh attachment time. The categorical variables were compared using chi-square or Fischer's Exact test, whereas the continuous variables were compared using Student's t-test or Mann-Whitney U test where appropriate. An intention-to-treat analysis was performed. Fifty-three participants were randomized, 26 to mesh attachment with anchor, 27 to mesh attachment with suture, and 81% (21/26) and 93% (25/27) had 12-month follow up respectively. There were no significant differences between the groups with regard to age (P=.12), body mass index (P=.23), stage of prolapse (P=.97), or other preoperative factors. Mesh attachment interval time was faster in the anchor compared to suturing study arm (12.2±7.8 vs 21.2±5.2 minutes; P<.001), while sacrocolpopexy times (107.6±33.2 vs 109.8±21.2 minutes; P=.774) were not different. The ease of placement for the surgeon based on a visual analog scale (P=.16), the appearance of the mesh attachment (P=.07), and the overall satisfaction with the use of the specific attachment type (P=.65) were similar for the arms. There was no difference in perioperative adverse events rates between arms and by 12 months follow-up there were no sacrocolpopexy mesh, anchor, or suture exposures. There was no difference in outcomes at 12 months including composite failure (10% vs 12%; P=.79), patient global impression of improvement (1.06 vs 1.19; P=.27), or patient pelvic pain (9.81 vs 9.67; P=.56). In patients undergoing a robotic-assisted sacrocolpopexy, the anchor vaginal mesh attachment technique required significantly less time than suturing. There was no difference between techniques in complications, failure, surgeon, or patient-reported outcomes through 12 months of follow-up. Mesh attachment during sacrocolpopexy can be performed in less time by using the anchor technique, providing surgeons with an alternative surgical technique for this procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call