Abstract

BackgroundArrhythmias are known as one of the complications of lung cancer surgery, and most of them are not lethal. Life-threatening arrhythmias have been reported in the literature but in reality very rare.Case presentationA 67-year-old Japanese man with a history of hypertension was diagnosed with squamous cell carcinoma in left lower lobe underwent a left lower lobectomy and bilateral mediastinal lymph node dissection through a median sternotomy. During lymph node dissection along the right vagus nerve, the patient’s heart rate and blood pressure dropped suddenly and an electrocardiogram monitor showed ST elevation. These abnormalities returned to normal soon after cardiac massage was performed and a coronary vasodilator was given. A temporary pacing wire was inserted at the end of the surgery. The postoperative course was uneventful and the patient was discharged on postoperative day 11 without a need for permanent pacemaker.ConclusionsWe present a patient who was complicated with lethal arrhythmias during lung cancer surgery for the purpose of elucidating, from anatomical viewpoint, the relationship between arrhythmias and the involvement of cardiac plexus during lymph node dissection. The result showed that arrhythmia was inadvertently elicited by cardiac plexus stimulation during lymph nodes dissection around the vagus nerve. It is important to be familiar not only with the course of phrenic, vagus, and recurrent laryngeal nerve but also the anatomy of cardiac plexus to prevent arrhythmic complications in lung cancer surgery.

Highlights

  • Arrhythmias are known as one of the complications associated with lung cancer surgery, and most of them are not lethal

  • We present a patient who was complicated with lethal arrhythmias during lung cancer surgery for the purpose of elucidating, from anatomical viewpoint, the relationship between arrhythmias and the involvement of cardiac plexus during lymph node dissection

  • The result showed that arrhythmia was inadvertently elicited by cardiac plexus stimulation during lymph nodes dissection around the vagus nerve

Read more

Summary

Introduction

Arrhythmias are known as one of the complications associated with lung cancer surgery, and most of them are not lethal. During lymph node dissection along the right vagus nerve, the patient’s heart rate and blood pressure dropped suddenly (Fig. 2) and an electrocardiogram monitor showed ST elevation. Case presentation: A 67-year-old Japanese man with a history of hypertension was diagnosed with squamous cell carcinoma in left lower lobe underwent a left lower lobectomy and bilateral mediastinal lymph node dissection through a median sternotomy. During lymph node dissection along the right vagus nerve, the patient’s heart rate and blood pressure dropped suddenly and an electrocardiogram monitor showed ST elevation These abnormalities returned to normal soon after cardiac massage was performed and a coronary vasodilator was given. The postoperative course was uneventful and the patient was discharged on postoperative day 11 without a need for permanent pacemaker

Objectives
Findings
Discussion
Conclusion
Full Text