Abstract

Purpose: To anatomically and radiographically describe tack location within the anterosuperior (AS) and posterosuperior (PS) aspects of the glenoid when performing simulated repairs of type II SLAP lesions. Type of Study: Cadaveric anatomic and radiographic analysis. Methods: Arthroscopy was performed on 7 fresh-frozen cadaveric shoulders and bioabsorbable tacks were placed in the AS and PS aspects of the glenoid to simulate repair of a type II SLAP lesion. The PS tack was placed through an accessory portal 1 cm lateral and 1 cm anterior to the posterolateral corner of the acromion. Dissection was then performed, and the incision made in the rotator cuff when creating the posterolateral accessory portal (PLAP) was identified and measured. Tack location within the glenoid was visually studied after removal of all soft tissues and recorded as being either completely within bone or partially within bone. The tacks were recannulated with guide pins and 3 radiographs were then taken of each specimen (true anteroposterior, axillary, and en face glenoid views) and angles of entry determined. In addition, the angle of deviation from the orthogonal at the point of entry of each tack was measured on the en face glenoid view. Results: The average incision made in the rotator cuff for creation of the PLAP measured 10.3 mm in maximum diameter. In 6 of 7 specimens, this incision was made through muscle and not tendon. Seven of 7 AS tacks were completely within bone, and only 5 of 7 PS tacks remained completely within bone. On the true anteroposterior view, the average angle of entry from the vertical for the AS tack was 64°. For the PS tack, this angle measured 86°. On the axillary view, the angle of placement from the coronal averaged 22° for the AS tack and 42° for the PS tack. For the en face glenoid view, the angle of entry from the vertical was 34° for the AS tack and 93° for the PS tack. Lastly, the angle of deviation from the orthogonal on the en face glenoid view was 12° and 35° for the AS and PS tacks, respectively. This difference was statistically significant at P <.001. Conclusions: This study provides quantitative data on the angle of placement and location of tacks within the superior glenoid when performing repairs of type II SLAP lesions. It also shows the PLAP to be a safe portal for the placement of devices into the posterosuperior aspect of the glenoid. Furthermore, the data show the AS tack to be more reliably placed than the PS tack.Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 18, No 4 (April), 2002: pp 366–371

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.