Abstract

Aboveground storage tanks are widely used for storage of liquids. The bottom of these tanks rest on the soil and is prone to the corrosion. Due to the use of geo-membrane liner in some cases, the bottoms of these tanks can only be protected from corrosion by using distributed mesh ribbon anodes. Up to now, there is no an accurate and comprehensive calculation for current distribution in such configurations. For this reason, the spans of the ribbon anodes and conductor bars are mostly chose based on simple and handy formulas, which may not be correct and optimum enough. Therefore, in this paper, the current distribution is calculated based on a 2D model and considering coating and polarization effect and then applied for determining the anodes span. Furthermore, the current attenuation in the ribbons and conductor bars are calculated for determining the spans between the conductor bars. Finally, based on the achieved formulas, two designs are presented and compared and the results of them are validated by Finite element method simulations. The results of this paper could be used for optimum design of cathodic protection systems for bottom of the above ground storage tanks.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.