Abstract
This article discusses a study done by the Washington Aqueduct, Washington, D.C. at the request of the U.S. Environmental Protection Agency (USEPA) to study its chloramination practices for minimizing the amount of free ammonia in the distribution system. One objective of the study was to determine a viable holding time window for the analysis of free ammonia in which the free ammonia level would not significantly increase from that at the time of sample collection. Previous practices are discussed, along with the field study method. Results are given and it was concluded that, considering the role that free ammonia plays in the nitrification process, a maximum holding time of 48 hrs. for free ammonia analysis is recommended. Further resources on this subject are listed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.