Abstract

Abstract Chemical therapy for control and prevention of fish diseases is a necessary and common practice in aquaculture. Many factors affect the accuracy of a chemical treatment application, such as the functioning of the chemical delivery system, calculation of chemical quantities to be delivered, water temperature, geometry of the culture unit, inlet-outlet structure, the influence of aerators, wind movement, and measurement of water volumes and flow rates. Three separate trials were conducted at the Osceola Fish Hatchery, a facility of the Wisconsin Department of Natural Resources, evaluating the accuracy of flow-through hydrogen peroxide treatments applied to 1, 3, or 9 raceways that were connected in series. Raceways were treated with 50 or 75 μL/L of hydrogen peroxide for 30 min. Chemical concentrations were determined titrimetrically. The target treatment regimen was not realized in any of the applications. Chemical concentrations dropped and exposure times increased with each additional raceway tr...