Abstract

A convective-diffusion equation with semi-infinite boundary conditions for rotating disk electrodes under the hydrodynamic conditions is discussed and analytically solved for electrochemical catalytic reactions. The steady-state catalytic current of the rotating disk electrode is derived for various possible values of parameters by using a new approach of the homotopy perturbation method. The theoretical approach in this paper is described, for the first time, on the basis of convection–diffusion equations for the kinetics of Fenton's reagent using a platinum rotating disk electrode. The obtained approximate analytical expression for the concentrations of ferric and ferrous ions for steady-state conditions are shown to be highly accurate when compared to numerical results and other approximations found in the literature. A sensitive analysis of parameters of the current and concentration is presented.

Highlights

  • November 2020A convective-diffusion equation with semi-infinite boundary conditions for rotating disk electrodes

  • The rotating disc electrode (RDE), known as the hydrodynamic working electrode, is the hydrodynamic electroanalytical technique used to limit the diffusion layer thickness

  • A system of a convection–diffusion equation in a finite domain modeling an EC-catalytic mechanism at the rotating disk electrode [31] and a system of convection– diffusion equations representing a pseudo-first-order EC-catalytic process at a rotating disc electrode in a finite domain [32]

Read more

Summary

November 2020

A convective-diffusion equation with semi-infinite boundary conditions for rotating disk electrodes. The steady-state catalytic current of the rotating disk electrode is derived for various author(s) and the title of the work, journal citation possible values of parameters by using a new approach of the homotopy perturbation method. Theoretical approach in this paper is described, for the first time, on the basis of convection–diffusion equations for the kinetics of Fentons reagent using a platinum rotating disk electrode. The obtained approximate analytical expression for the concentrations of ferric and ferrous ions for steady-state conditions are shown to be highly accurate when compared to numerical results and other approximations found in the literature.

Introduction
Mathematical formulation of the problem
Analytical expressions of concentrations and current
Previous analytical results
Results and discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.