Abstract
The analytical solutions for condensation (and evaporation) rates of laminar humid air flow in the channels of a battery pack at both entrance and downstream regions are obtained/modeled. The effects of the entrance fluid velocity profile and the aspect ratio of the flow channel are taken into consideration. Initially, an analytical solution for laminar humid air flows' condensation at the flow channel with infinite aspect ratio and fully developed flow profile at the entrance is obtained. The solution is in good agreement with the simulation result obtained from a correlated fluent condensation model. After performing simulations of water vapor condensation and evaporation in the flow channel for different aspect ratios and entrance velocity profiles, the analytical solutions of condensation and evaporation rate of water vapor are presented in analytic forms by adding appropriate coefficients/correction factors to the solution for the flow in the channel with infinite aspect ratio. The resulting model accurately captures the effects of the entrance velocity profile and aspect ratio.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.